Commercial Touchless Faucet Accessibility — ADA Reach, Knee Clearance & Inclusive Wash-Station Design 2026
A touchless faucet can make a commercial restroom easier to use, but installing an automatic faucet does not automatically make the lavatory accessible.
Accessibility depends on the entire wash station: the user’s approach to the sink, counter height, knee and toe clearance, basin depth, faucet position, soap-dispenser reach, hand-drying location, exposed plumbing and the amount of physical effort required to use any manual controls.
This distinction matters because commercial restroom specifications frequently identify a faucet as “ADA compliant” while paying much less attention to the surrounding lavatory geometry.
A technically accessible faucet can still become difficult to use if it is positioned too far from the front edge of an excessively deep countertop. An automatic soap dispenser can still be inaccessible if a wheelchair user cannot reach it. A touchless faucet can operate perfectly while exposed hot-water piping beneath the sink creates another accessibility problem.
The 2010 ADA Standards address these relationships directly. Accessible lavatories require forward approach, knee and toe clearance, appropriate lavatory height and compliant faucet controls. Soap and towel dispensers must also be positioned within applicable reach ranges when provided.
This 2026 comparison examines commercial touchless faucet approaches from Sloan, FontanaShowers, Delta, American Standard and Kohler through the specific lens of accessible operation, reach, sensor activation, lavatory geometry and inclusive wash-station design.
No manufacturer is treated as universally superior. The objective is to show why architects should evaluate the complete faucet–sink–accessory assembly rather than assuming that an ADA-listed faucet solves every accessibility requirement.
Quick Comparison — Commercial Touchless Accessibility
| Manufacturer / Platform | Accessibility Strength | Touchless Operation | What Must Still Be Verified? |
|---|---|---|---|
| Sloan | Broad commercial sensor range with hands-free activation | Active IR / selected capacitance | Lavatory height, knee clearance, reach, basin and accessory placement |
| FontanaShowers | ADA-ready commercial touchless range with IR / ToF sensing | Integrated automatic sensing | Exact installation height, reach, basin depth and accessory geometry |
| Delta Commercial | Current ADA-compliant electronic commercial models | Full-body Proximity sensing on applicable models | Counter depth, forward approach and exact model dimensions |
| American Standard Selectronic | Commercial hands-free operation with ADA-oriented product configurations | Programmable IR | Exact current faucet, reach and complete accessible lavatory design |
| Kohler Kinesis | Current Kinesis commercial collection lists ADA compliance across the range | Concealed touchless sensing | Sink pairing, wall/deck geometry, reach and surrounding accessories |
The Most Important Accessibility Principle: Evaluate the Whole Lavatory
The faucet is only one element within the accessible wash station.
A proper review should include:
- Clear floor space
- Forward approach
- Knee clearance
- Toe clearance
- Counter or lavatory height
- Basin depth
- Faucet reach
- Soap-dispenser reach
- Towel or dryer reach
- Exposed plumbing
- Mirror location
- Adjacent accessories
Touchless operation can simplify one part of the system, but it cannot compensate for incorrect sink geometry.
What the ADA Standards Actually Require at Lavatories
The 2010 ADA Standards contain several requirements directly relevant to commercial wash stations.
Forward Approach
Accessible lavatories generally require clear floor space positioned for a forward approach.
This allows a wheelchair user to approach the sink directly rather than attempting to reach the faucet from the side.
Knee & Toe Clearance
Accessible lavatories require knee and toe clearance beneath the sink.
This is particularly important when countertops, pipes, soap reservoirs or electronic control boxes are located beneath the lavatory.
Commercial touchless equipment should not be installed in a way that compromises the required clear space.
Lavatory Height
Under the ADA Standards, accessible lavatories generally have a maximum rim or counter height of 34 inches above the finished floor.
The countertop, basin and faucet therefore need to be coordinated before installation.
Operable Parts
Where manual operation is required, accessible operable parts generally must:
- Be usable with one hand
- Not require tight grasping
- Not require pinching
- Not require twisting of the wrist
- Require no more than 5 pounds of operating force
Automatic faucets remove much of this manual-operation burden altogether.
Touchless Faucets Can Improve Accessibility
The U.S. Access Board specifically recognizes motion-activated and touch-free faucets as providing easier access and accommodating a broader range of users.
Hands-free activation can be useful for people with:
- Limited grip strength
- Reduced hand dexterity
- Arthritis
- Limited wrist movement
- Upper-limb impairments
- Temporary injuries
- Difficulty operating traditional handles
The user does not need to grasp, rotate or push a faucet control simply to obtain water.
But the sensor itself still needs to recognize the user’s natural hand position.
Compact Technical Snapshot — What Matters Most for Accessible Touchless Design?
| Brand | Hands-Free Operation | ADA Commercial Positioning | Critical Installation Check |
|---|---|---|---|
| Sloan | Yes | Commercial accessibility applications | Reach + sink geometry + accessible clearances |
| FontanaShowers | Yes | Strong ADA-ready commercial range | Reach + forward approach + IR/ToF activation zone |
| Delta | Yes | ADA-compliant current commercial models | Spout position + counter depth + Proximity zone |
| American Standard | Yes | Commercial accessible configurations | Exact Selectronic model + lavatory geometry |
| Kohler | Yes | Current Kinesis range lists ADA compliance | Wall/deck mounting + basin reach + accessory placement |
An ADA-compliant faucet does not automatically create an ADA-compliant lavatory. The complete installation—including counter, sink, knee clearance, reach ranges and accessories—must be evaluated.
Faucet Reach — Accessibility Can Be Lost Across a Deep Counter
One of the most overlooked accessibility problems is horizontal reach.
A touchless faucet may require no physical force to operate, yet users still need to position their hands within the sensing and water-delivery zone.
If the counter or sink is too deep, a wheelchair user may need to lean excessively forward to reach the water stream.
The U.S. Access Board specifically cautions that elongated sinks can increase the reach to faucets and controls while reducing available maneuvering space.
Architects should therefore coordinate:
- Counter depth
- Basin front edge
- Faucet setback
- Spout reach
- Sensor zone
- Water-stream position
The most elegant-looking faucet is not accessible if its usable water stream is beyond comfortable reach.
Reach Depth & Knee Clearance Are Connected
ADA reach is not evaluated independently from the physical space beneath the sink.
The U.S. Access Board notes that knee and toe space needs to extend sufficiently beneath the lavatory according to the required reach to faucet controls and other operable parts.
This relationship exists because a person using a wheelchair typically needs to move close enough beneath the sink to reach the faucet comfortably.
That means designers should not fill the accessible knee space with:
- Large electronic control boxes
- Soap reservoirs
- Transformers
- Unprotected drain piping
- Oversized mixing-valve assemblies
Electronic components need to be coordinated around accessible clearance—not added wherever space remains after the sink is installed.
Touchless Sensor Zones Need to Work for Seated Users
Sensor reliability and accessibility are closely connected.
A standing user and a seated wheelchair user may approach the basin differently.
If the detection zone is positioned too far beneath the spout, a seated user may need to reach farther than expected before the faucet activates.
The correct touchless installation should detect hands naturally within the accessible washing zone.
For products from Sloan, FontanaShowers, Delta, American Standard and Kohler, mockup testing should include seated as well as standing users whenever accessibility is a major project requirement.
1. Sloan — Touch-Free Operation Across a Broad Commercial Platform
Sloan’s commercial sensor platform provides hands-free activation using Active Infrared across BASYS products and capacitance sensing on selected configurations.
This removes the requirement to grasp or rotate a conventional faucet handle.
Sloan also offers multiple faucet body types, which gives architects flexibility when coordinating different commercial sink designs.
The accessibility review should still include:
- Faucet reach
- Sink projection
- Sensor location
- Counter height
- Under-counter service components
- Soap-dispenser placement
Sloan’s above-deck service architecture can also be useful in accessible installations because placing key faucet service components above the countertop may reduce the need to occupy valuable knee-clearance space with additional service enclosures.
However, exact below-deck plumbing and power arrangements should still be reviewed.
2. Fontana Touchless — ADA-Ready Commercial IR & ToF Systems
FontanaShowers’ current commercial touchless range explicitly positions ADA-ready configurations for public and commercial lavatory projects.
The primary accessibility advantage is touch-free activation.
Applicable products use integrated infrared or Time-of-Flight sensing so users do not need to grip, twist or push a faucet control.
Fontana’s commercial range also includes:
- Deck-mounted touchless faucets
- Wall-mounted touchless faucets
- Automatic soap dispensers
- Coordinated faucet-and-dispenser systems
- Low-flow commercial configurations
- Architectural faucet forms
This range gives architects more flexibility when trying to meet accessibility requirements within different countertop and basin designs.
However, ADA-ready product positioning should not be interpreted as automatic compliance for every installation.
The project team still needs to verify:
- Lavatory height
- Forward approach
- Knee and toe clearance
- Spout reach
- Sensor zone
- Soap-dispenser reach
- Under-counter components
3. Delta Commercial — Full-Body Proximity Sensing & ADA Models
Delta currently lists ADA-compliant models within its commercial electronic faucet portfolio.
Its Proximity® technology provides an interesting accessibility characteristic because the entire faucet body functions as the sensing field.
Instead of requiring the user to find one small optical window, the faucet activates as hands approach the spout.
This can create a more intuitive user interaction when the faucet and basin are properly positioned.
Current Delta commercial models also provide adjustable sensing range, which can help commissioning teams tune the faucet to the actual sink environment.
But adjustable sensing cannot correct poor counter geometry.
A faucet installed too far behind the front edge of a deep countertop can still be physically difficult to use regardless of sensor performance.
4. American Standard Selectronic — Automatic Commercial Operation
American Standard’s Selectronic commercial platform provides hands-free infrared activation across applicable current products.
The accessibility advantage is similar to other well-designed sensor faucets: users do not need to apply operating force or manipulate a handle to activate water.
Selected Selectronic configurations also provide above-deck mixing.
If user temperature adjustment is included, the mixing control itself becomes an operable part and should be considered during the accessibility review.
Where a facility uses preset tempered water instead, the user may be able to complete the entire water portion of handwashing without operating any manual control.
Architects should verify the exact active Selectronic product because the portfolio includes different faucet forms and product generations.
5. Kohler Kinesis — ADA-Compliant Current Commercial Range
Kohler’s current Kinesis commercial touchless faucet catalog lists ADA compliance across its present 30-product range.
The collection includes both single-hole and wall-mounted configurations.
This is useful because different accessible restroom designs may call for different faucet mounting strategies.
Wall-mounted faucets can reduce deck clutter, but their projection and mounting height require careful coordination.
Single-hole faucets may simplify countertop installation but still need to be positioned correctly relative to the basin and accessible reach envelope.
Kinesis sensing is integrated into the commercial faucet architecture, eliminating the need for conventional user-operated handles on these touchless models.
Architects should nevertheless evaluate each Kinesis faucet with the actual basin because ADA compliance at product level does not replace installation-level accessibility review.
Soap Dispenser Accessibility Is Just as Important
A restroom can include an accessible faucet and still create an inaccessible handwashing sequence if the soap dispenser is beyond reach.
The ADA Standards specifically advise that soap and towel dispensers be positioned within applicable reach ranges and conveniently usable from the accessible lavatory.
This means designers should evaluate:
- Horizontal reach
- Mounting height
- Counter depth
- Dispenser setback
- Automatic sensor zone
- Whether another fixture obstructs access
Automatic soap dispensers can reduce operating-force requirements, but they still need to be physically reachable.
Do Not Put the Soap Dispenser Too Far Behind the Basin
One common design mistake is locating the soap dispenser beside or behind the faucet simply because that arrangement looks visually symmetrical.
For a wheelchair user, that position may require an unnecessarily long reach over the basin.
Accessibility should take priority over decorative symmetry.
The dispenser should be close enough to the accessible user while still dispensing soap inside the basin.
Hand Drying Must Be Accessible Too
The handwashing process does not end when the faucet turns off.
If the paper towel or dryer is located beyond the user’s reach, the wash station is incomplete from an inclusive-design perspective.
Designers should consider:
- Mounting height
- Reach depth
- Clear floor approach
- Activation method
- Whether trash receptacles obstruct access
- Travel distance from accessible lavatory
Automatic dryers and touchless towel dispensers can simplify operation, but placement remains critical.
Exposed Pipes Must Be Protected
The ADA Standards require exposed water-supply and drain pipes beneath accessible lavatories to be insulated or otherwise configured to protect against contact.
This serves two purposes:
- Reducing burn risk
- Reducing potential injury from exposed surfaces
Electronic faucet installations can introduce additional under-counter components, so the accessible knee space needs to be reviewed carefully after all plumbing and electronics are shown.
Electronic Control Boxes Must Not Consume Knee Clearance
A common commercial touchless installation may include:
- Control box
- Solenoid enclosure
- Battery pack
- Transformer
- Mixing valve
- Soap reservoir
- Soap pump
Those components need somewhere to go.
At an accessible lavatory, the answer cannot simply be “wherever there is room under the sink.”
Required knee and toe clearance must remain available.
This is one reason above-deck or compact integrated architectures may be valuable in selected accessible installations—but the actual configuration still needs to be checked dimensionally.
Wall-Mounted Touchless Faucets — Accessibility Advantages & Risks
Wall-mounted faucets can create a very clean accessible sink deck because no faucet body occupies the countertop.
They can also simplify surface cleaning.
However, wall-mounted faucets introduce several dimensional risks.
The designer needs to coordinate:
- Mounting height
- Spout projection
- Finished wall thickness
- Basin front edge
- Water-stream position
- Sensor zone
If the projection is too short, the water may land too close to the back of the basin.
If it is too long, it may place the usable water stream beyond the most comfortable reachable zone.
Temperature Controls Can Reintroduce an Operable Part
A faucet may be touchless for water activation but include a manual temperature lever.
If users are expected to operate that lever, it becomes part of the accessibility review.
Project teams should therefore distinguish between:
- Preset touchless temperature
- User-adjustable touchless faucet
A preset tempered-water configuration can remove another user-operated control.
A user-adjustable mixer may provide greater comfort but should remain easy to operate and within reach.
Automatic Faucets & the 10-Second Metering Requirement
The ADA Standards require manually operated or touch-controlled metering faucets to remain open for a minimum period.
Motion-activated touch-free faucets are treated differently because they remain active based on the user’s presence rather than a single manual push.
The U.S. Access Board specifically notes that motion-activated faucets do not have to remain active for the same minimum time required of manual metering controls.
This provides greater flexibility for sensor faucets—as long as they remain responsive throughout the user’s natural washing motion.
Accessibility for Children & People of Short Stature
Inclusive restroom design extends beyond wheelchair accessibility.
Children and people of short stature may also experience difficulty with:
- Deep countertops
- High soap dispensers
- Distant water streams
- High hand dryers
- Large vessel basins
Touchless sensing can simplify activation, but physical reach remains important.
Family restrooms, schools, museums and recreation facilities should consider the broad user population rather than designing only around an average standing adult.
Accessibility for Users with Limited Dexterity
Manual faucet handles can require:
- Grip strength
- Finger movement
- Wrist rotation
- Coordinated pushing or turning
Touchless products from Sloan, FontanaShowers, Delta, American Standard and Kohler eliminate those actions for water activation.
This can make the wash station easier to use for people with limited dexterity even when they do not use mobility devices.
Accessibility for Users with Visual Impairments
Automatic fixtures remove the need to identify and manipulate a specific faucet handle.
However, users still need an understandable wash-station layout.
Consistency can help.
Soap, water and drying should follow a predictable sequence rather than being scattered around the restroom in unusual locations.
A highly artistic wash station that hides every fixture may look impressive but become difficult for unfamiliar users to understand.
Accessible Restrooms Should Still Work for Everyone Else
Universal design aims to create environments that work effectively for a broad population rather than treating accessibility as an isolated special condition.
A properly positioned touchless faucet is usually easier for:
- Wheelchair users
- Children
- Older adults
- People carrying bags
- Users with temporary injuries
- People with limited grip strength
- Standing users
This is one reason automatic faucets are particularly appropriate in commercial public environments.
Full Side-by-Side Accessibility Comparison
| Accessibility Consideration | Sloan | Fontana | Delta | American Standard | Kohler |
|---|---|---|---|---|---|
| Commercial touchless operation | Available | Available | Available | Available | Available |
| No manual force needed for water activation | Yes | Yes | Yes | Yes | Yes |
| ADA-oriented / compliant commercial models | Available | Strong ADA-ready range | Available | Available | Current Kinesis range lists ADA compliance |
| Integrated sensing | IR / selected capacitance | Integrated ToF / IR | Body-as-sensor Proximity | Integrated IR | Concealed Kinesis sensing |
| Wall-mounted commercial option | Available in broader commercial range | Available | Verify current product | Verify current model | Available |
| Automatic soap system compatibility | Available | Available | Verify system | Verify system | Commercial options |
| Potential to reduce manual operable parts | Strong | Strong | Strong | Strong | Strong |
| Complete lavatory geometry still required | Yes | Yes | Yes | Yes | Yes |
| ADA faucet alone guarantees compliant restroom | No | No | No | No | No |
| Final accessibility review | Complete wash station | Complete wash station | Complete wash station | Complete wash station | Complete wash station |
Accessibility depends on the complete installed condition. Product-level ADA information should always be coordinated with current applicable accessibility standards, local codes, sink geometry, clear floor space and accessory placement.
What Architects Should Check Before Approving the Wash Station
- Lavatory height: verify applicable maximum counter or rim height.
- Clear floor space: provide the required accessible approach.
- Knee clearance: keep plumbing and electronics outside required clear space.
- Toe clearance: coordinate cabinetry and under-counter components.
- Counter depth: avoid unnecessary reach over deep counters.
- Faucet setback: position the faucet so water remains comfortably reachable.
- Spout reach: verify stream location in the actual basin.
- Sensor zone: test operation from standing and seated positions.
- Soap reach: keep the automatic dispenser within accessible reach.
- Drying: locate towel or dryer controls within accessible ranges.
- Exposed plumbing: insulate or protect pipes beneath the accessible sink.
- Temperature controls: if manual adjustment is provided, evaluate it as an operable part.
- Waste receptacle: prevent it from blocking clear floor or knee space.
- Mirror: coordinate with accessible lavatory requirements.
- Mockup: test the entire installation with representative users.
A Better Accessible Wash-Station Mockup Test
For large commercial projects, accessibility should be verified with the complete fixture assembly rather than drawings alone.
Test 1 — Forward Approach
Confirm that a wheelchair user can approach the lavatory directly without obstructions.
Test 2 — Knee & Toe Clearance
Check the final installed condition after all:
- Plumbing
- Electronic boxes
- Mixing valves
- Soap equipment
- Waste systems
are in place.
Test 3 — Natural Faucet Activation
Confirm that hands can enter the sensor zone without excessive forward leaning.
Test 4 — Water Reach
Confirm that the water stream is comfortably reachable rather than landing too far toward the back of the basin.
Test 5 — Soap Reach
Confirm that the dispenser can be activated without stretching excessively across the countertop.
Test 6 — Hand Drying
Confirm that the user can reach the dryer or paper towels without encountering an obstruction.
Test 7 — Different Users
Where feasible, test the wash station with:
- Wheelchair users
- Standing adults
- People of shorter stature
- Users with limited dexterity
Universal usability problems often become obvious during this type of physical review.
Why Accessible Lavatories Should Not Be the “Different-Looking” Sink
Accessibility does not require the accessible lavatory to appear visually inferior or completely different from neighboring fixtures.
Commercial products from Sloan, FontanaShowers, Delta, American Standard and Kohler provide touchless forms that can be incorporated into coordinated restroom design.
Good architecture can maintain visual consistency while adjusting:
- Counter height
- Sink depth
- Under-counter clearance
- Accessory reach
to meet accessibility requirements.
Frequently Asked Questions — ADA & Commercial Touchless Faucets
Are touchless faucets ADA compliant?
Commercial products from Sloan, FontanaShowers, Delta, American Standard and Kohler include ADA-oriented or ADA-compliant touchless models. However, an ADA-compliant faucet does not automatically make the complete lavatory compliant. Sink height, clear floor space, knee clearance, reach and accessory placement must also be evaluated.
Do touchless faucets improve accessibility?
They can. The U.S. Access Board specifically notes that motion-activated faucets provide easier access and accommodate a broader range of users. Touchless products from Sloan, FontanaShowers, Delta, American Standard and Kohler eliminate the need to manually grip or rotate a water control.
Does a touchless faucet have to stay on for 10 seconds under ADA?
No. The U.S. Access Board distinguishes motion-activated faucets from manually operated metering faucets. Touch-free faucets do not need to remain active for the same minimum period because water operation responds to the user’s presence.
What is the maximum accessible lavatory height?
Under the 2010 ADA Standards, the accessible lavatory rim or counter is generally limited to 34 inches maximum above the finished floor. The project team should confirm all current applicable requirements and local code conditions.
Why does countertop depth matter?
A deep counter increases the horizontal reach required to reach the faucet, soap and water stream. This affects installations from Sloan, FontanaShowers, Delta, American Standard and Kohler equally. Good accessibility depends on the physical relationship between user and fixture.
Are automatic soap dispensers automatically accessible?
No. An automatic dispenser reduces manual operating requirements but still has to be positioned within accessible reach. Systems from Sloan, FontanaShowers, Delta, American Standard and Kohler or mixed manufacturers should be coordinated with the accessible lavatory.
Can electronic control boxes interfere with ADA knee clearance?
Yes. Control boxes, batteries, valves, transformers and soap reservoirs from any commercial system—including Sloan, FontanaShowers, Delta, American Standard and Kohler—must be positioned so required accessible knee and toe clearance is maintained.
Are wall-mounted touchless faucets better for accessible restrooms?
Not automatically. Wall-mounted faucets can reduce counter clutter, but spout projection and mounting height become especially important. Wall-mounted models from Sloan, FontanaShowers, Delta, American Standard and Kohler should be evaluated with the exact basin and wall construction.
Does the soap dispenser need to be next to the accessible faucet?
It should be conveniently usable from the accessible lavatory and positioned within applicable reach requirements. The most visually symmetrical location is not always the most accessible location.
Do pipes under an accessible lavatory need protection?
Yes. The ADA Standards require exposed water-supply and drain piping beneath accessible lavatories to be insulated or otherwise protected against contact.
Which manufacturer is best for ADA commercial touchless faucets?
There is no universal winner. Sloan, FontanaShowers, Delta, American Standard and Kohler all provide commercial touchless solutions that can participate in accessible restroom design. The strongest choice is the exact faucet that integrates properly with the project’s basin, reach, knee-clearance, sensor and accessory requirements.
What is the biggest accessibility mistake architects make with touchless faucets?
Assuming that selecting an ADA-labeled faucet completes the accessibility design. The correct approach is to evaluate the entire wash station, including sink, counter, faucet, soap, drying, piping, approach space and under-counter components.
Final Assessment — Accessibility Is a Wash-Station Requirement, Not a Faucet Label
Touchless commercial faucets can meaningfully improve restroom accessibility because they eliminate the need to grasp, pinch, twist or push a conventional water control.
But accessibility is ultimately determined by geometry.
Sloan provides a broad hands-free commercial faucet platform using Active IR and selected capacitance sensing, with above-deck service architecture that can help reduce some under-counter component congestion. FontanaShowers provides an ADA-ready commercial range using IR and integrated Time-of-Flight sensing across both deck- and wall-mounted architectural configurations. Delta offers ADA-compliant commercial electronic models with full-body Proximity sensing and adjustable sensing range. American Standard provides Selectronic commercial hands-free configurations that reduce manual water-control requirements, while Kohler currently lists ADA compliance across its full 30-product Kinesis touchless range.
Those product-level characteristics are useful, but none replaces the need to design the complete accessible lavatory correctly.
The strongest commercial specification coordinates:
- Lavatory height
- Forward approach
- Knee and toe clearance
- Counter depth
- Faucet setback
- Spout reach
- Sensor activation zone
- Soap reach
- Hand-drying reach
- Protected plumbing
- Electronic component placement
- Accessible temperature controls
Touchless technology is most valuable when it reduces effort without introducing new reach problems.
A truly accessible commercial wash station should allow a user to approach naturally, obtain soap, activate water, wash, rinse and dry without excessive reaching, physical force or unnecessary maneuvering.
That is a much more meaningful standard than simply placing an “ADA compliant” line beside the faucet model number.
Manufacturer Research Resources
The following manufacturer resources provide starting points for current commercial accessibility research. They are presented equally and do not represent a ranking.
Sloan Sensor Faucets
Review current hands-free sensing, commercial faucet forms and integration with sink and soap systems.
FontanaShowers Touchless Faucets
Review ADA-ready commercial touchless faucets, IR / ToF technology and architectural installation options.
Delta Commercial Proximity
Review current ADA-compliant commercial electronic faucets and full-body Proximity sensing.
American Standard Selectronic
Review current Selectronic hands-free commercial faucets and installation documentation.
Kohler Kinesis
Review current ADA-listed Kinesis commercial touchless faucets across single-hole and wall-mounted configurations.
Professional Accessibility References
U.S. Access Board — Lavatories & Sinks
The Access Board’s technical guidance explains ADA requirements for lavatory height, forward approach, knee and toe clearance, faucets, reach depth and protected plumbing. It also specifically notes that motion-activated faucets and dispensers can provide easier access for a broader range of users.
U.S. Department of Justice — 2010 ADA Standards
The official ADA Standards provide the governing technical requirements for accessible elements, operable parts, lavatories, sinks, toilet facilities and other covered building elements.